Protocol Converters
BACnet to MQTT Converter
- BACnet
- PoE
- Indoor
Bridges BACnet IP/MS/TP building automation networks to MQTT brokers, enabling cloud analytics, dashboards, and IIoT platform integration without replacing existing BMS infrastructure.
Specifications
| Input | BACnet IP + BACnet MS/TP |
|---|---|
| Output | MQTT v3.1.1 / v5.0 |
| Max BACnet Objects | 1000 |
| TLS | Yes (TLS 1.2 / 1.3) |
| Broker | Any standard MQTT broker |
| Power | 24VDC or PoE |
| Configuration | Web UI |
| Certifications | CE, BACnet BTL |
Specifications may vary by model and region. Final selection is confirmed during solution design.
Applications
Where the BACnet to MQTT Converter is used
Protocol converters let you keep the meters, controllers and equipment you already own. They read Modbus, BACnet or other field protocols and deliver the data over LoRaWAN or IP to your platform.
- Wireless retrofit of Modbus energy meters, BTU meters and flow meters
- Bringing BACnet BMS data into IoT platforms over MQTT
- Sending platform commands back into BACnet controllers
- Connecting equipment in locations where running new cable is not possible
How it connects
The BACnet to MQTT Converter sits between your existing field equipment and the network. It reads BACnet data from meters, controllers or the BMS on one side and delivers it on the other side to your network or platform, with the register or object mapping, scaling and payload decoding configured during commissioning.
Installation notes for UAE projects
- We confirm every device's register or object map before installation; compatibility is validated per model.
- Polling interval and payload size are planned so a converter's data fits within LoRaWAN airtime limits.
- Payload decoders are provided for the network server so data arrives as named, scaled values.
- Two-way (downlink) writes are used only where the use case needs them, and are rate-limited.
FAQ
Protocol Converters — questions
How many Modbus devices can one converter read?
It depends on the model, the number of registers and the reporting interval. Several devices on one RS485 bus is common; we size this during design so LoRaWAN airtime limits are respected.
Can a converter write values back to equipment?
Yes, where the converter and the device support it. Writes are sent as LoRaWAN downlinks and mapped to Modbus registers or BACnet objects.
Do you supply payload decoders?
Yes. We provide and test decoders for the network server so the data is usable immediately.
Used in
Solutions using this device
Related
More protocol converters
Selecting devices for a project?
Tell us about your site, assets and existing systems. A LoRaWAN specialist will review your requirements and propose a practical architecture — no obligation.