Skip to content
MatrixAILORAWAN
Modbus to LoRaWAN Converter — Modbus Protocol Converters

Protocol Converters

Modbus to LoRaWAN Converter

  • Modbus
  • DC
  • Indoor

Transparent protocol bridge converting Modbus RTU/TCP registers to LoRaWAN uplinks, enabling legacy meters and sensors to join modern IoT networks without replacement.

Specifications

InputModbus RTU (RS-485) / Modbus TCP
OutputLoRaWAN Class C
Max Registers200 per device
Poll IntervalConfigurable (10 s–1 h)
Power12–24VDC
ConfigurationWeb UI / JSON template
ProtectionIP20
CertificationsCE, RoHS

Specifications may vary by model and region. Final selection is confirmed during solution design.

Applications

Where the Modbus to LoRaWAN Converter is used

Protocol converters let you keep the meters, controllers and equipment you already own. They read Modbus, BACnet or other field protocols and deliver the data over LoRaWAN or IP to your platform.

  • Wireless retrofit of Modbus energy meters, BTU meters and flow meters
  • Bringing BACnet BMS data into IoT platforms over MQTT
  • Sending platform commands back into BACnet controllers
  • Connecting equipment in locations where running new cable is not possible

How it connects

The Modbus to LoRaWAN Converter sits between your existing field equipment and the network. It reads Modbus data from meters, controllers or the BMS on one side and delivers it on the other side to your network or platform, with the register or object mapping, scaling and payload decoding configured during commissioning.

Modbus to LoRaWAN integration →

Installation notes for UAE projects

  • We confirm every device's register or object map before installation; compatibility is validated per model.
  • Polling interval and payload size are planned so a converter's data fits within LoRaWAN airtime limits.
  • Payload decoders are provided for the network server so data arrives as named, scaled values.
  • Two-way (downlink) writes are used only where the use case needs them, and are rate-limited.

FAQ

Protocol Converters — questions

How many Modbus devices can one converter read?

It depends on the model, the number of registers and the reporting interval. Several devices on one RS485 bus is common; we size this during design so LoRaWAN airtime limits are respected.

Can a converter write values back to equipment?

Yes, where the converter and the device support it. Writes are sent as LoRaWAN downlinks and mapped to Modbus registers or BACnet objects.

Do you supply payload decoders?

Yes. We provide and test decoders for the network server so the data is usable immediately.

Used in

Solutions using this device

Selecting devices for a project?

Tell us about your site, assets and existing systems. A LoRaWAN specialist will review your requirements and propose a practical architecture — no obligation.