Skip to content
MatrixAILORAWAN
MQTT to BACnet Converter — MQTT Protocol Converters
MQTT to BACnet Converter view 2
MQTT to BACnet Converter view 3

Protocol Converters

MQTT to BACnet Converter

  • MQTT
  • PoE
  • Indoor

Publishes MQTT topics as virtual BACnet objects, allowing cloud-connected IoT sensors to appear natively in BACnet building automation controllers and BMS dashboards.

Specifications

InputMQTT v3.1.1 / v5.0
OutputBACnet IP Server
Virtual ObjectsUp to 500 AI/AO/BI/BO/AV
TLSYes
Power24VDC or PoE
ConfigurationWeb UI / REST API
NetworkGigabit Ethernet
CertificationsCE, BACnet BTL

Specifications may vary by model and region. Final selection is confirmed during solution design.

Applications

Where the MQTT to BACnet Converter is used

Protocol converters let you keep the meters, controllers and equipment you already own. They read Modbus, BACnet or other field protocols and deliver the data over LoRaWAN or IP to your platform.

  • Wireless retrofit of Modbus energy meters, BTU meters and flow meters
  • Bringing BACnet BMS data into IoT platforms over MQTT
  • Sending platform commands back into BACnet controllers
  • Connecting equipment in locations where running new cable is not possible

How it connects

The MQTT to BACnet Converter sits between your existing field equipment and the network. It reads MQTT data from meters, controllers or the BMS on one side and delivers it on the other side to your network or platform, with the register or object mapping, scaling and payload decoding configured during commissioning.

MQTT & REST API integration →

Installation notes for UAE projects

  • We confirm every device's register or object map before installation; compatibility is validated per model.
  • Polling interval and payload size are planned so a converter's data fits within LoRaWAN airtime limits.
  • Payload decoders are provided for the network server so data arrives as named, scaled values.
  • Two-way (downlink) writes are used only where the use case needs them, and are rate-limited.

FAQ

Protocol Converters — questions

How many Modbus devices can one converter read?

It depends on the model, the number of registers and the reporting interval. Several devices on one RS485 bus is common; we size this during design so LoRaWAN airtime limits are respected.

Can a converter write values back to equipment?

Yes, where the converter and the device support it. Writes are sent as LoRaWAN downlinks and mapped to Modbus registers or BACnet objects.

Do you supply payload decoders?

Yes. We provide and test decoders for the network server so the data is usable immediately.

Used in

Solutions using this device

Selecting devices for a project?

Tell us about your site, assets and existing systems. A LoRaWAN specialist will review your requirements and propose a practical architecture — no obligation.