Skip to content
MatrixAILORAWAN
Edge Controllers — BACnet HVAC & Building Sensors
Edge Controllers view 2
Edge Controllers view 3

HVAC & Building Sensors

Edge Controllers

  • BACnet
  • AC
  • Indoor

The MatrixAI IoT Edge Controller (MAI-2026) is a powerful, industrial-grade edge computing device designed for smart building, industrial automation, and IoT applications. It enables real-time data acquisition, processing, and communication across multiple protocols, making it ideal for Facilities Management, BMS, Energy Monitoring, and Smart Infrastructure. With support for LoRaWAN, 4G/LTE, Wi-Fi, NB-IoT, and Modbus, the MAI-2026 acts as a central gateway for connecting sensors, devices, and cloud platforms.

Specifications

ProtocolsBACnet IP/MS/TP, Modbus RTU/TCP, MQTT
ProcessorARM Cortex-A7 1GHz
Memory512MB RAM, 8GB Flash
NetworkDual Ethernet + Wi-Fi
Power24VAC/DC
ProtectionIP20
CertificationsCE, UL, BACnet BTL

Specifications may vary by model and region. Final selection is confirmed during solution design.

Applications

Where the Edge Controllers is used

HVAC and building sensors give FM teams visibility of air handling, ducts, valves and plant between maintenance visits, and let control strategies run on real measurements.

  • Duct temperature, humidity and CO₂ monitoring on AHUs
  • Filter condition alerts from differential pressure
  • Chilled-water valve control and actuator feedback
  • Digital and analog I/O for legacy equipment status and alarms
  • Edge controllers bridging field devices to BACnet, Modbus or MQTT

How it connects

The Edge Controllers uses BACnet, so it integrates directly with most building management systems. Its data can also be bridged to MQTT for IoT platforms and analytics, or combined with LoRaWAN sensors on the same project.

BACnet to LoRaWAN integration →

Installation notes for UAE projects

  • BACnet and Modbus devices are mapped into the existing BMS object list so operators keep their familiar interface.
  • Where cabling is impractical, I/O signals can be carried over LoRaWAN with a converter.
  • Plant rooms are often RF-difficult; LoRa Mesh or an in-room gateway can be used.

FAQ

HVAC & Building Sensors — questions

Will these devices work with our existing BMS?

Devices with BACnet or Modbus interfaces integrate directly. LoRaWAN devices are integrated through a network server and a BACnet or Modbus mapping layer.

Can legacy plant with only dry contacts be monitored?

Yes. Digital and analog input devices read run status, alarms and 4–20 mA or 0–10 V signals and report them wirelessly.

Selecting devices for a project?

Tell us about your site, assets and existing systems. A LoRaWAN specialist will review your requirements and propose a practical architecture — no obligation.